A Hygrometer measures the Value of Humidity Directly.Generally,the output of Hygrometer is used to indicate Relative Humidity. Several Material exhibit changes in Electric Properties that are caused by Humidity.These are frequently used in Transducers that are designed and Calibrated to read Relative Humidity Directly. 01)Resistive Hygrometer:- Some Hygroscopic Salts exhibit a change in Resistivity with Humidity.The most common is Lithium hloride.This,with a Binder may be coated on a wire or on Electrodes. Resulting Resistance changes cover a wide range for example 10 raise to four to 10 raise to nine ohm,as the Humidity changes from 100 to 0 percent. This makes it impracticle to design a single element to operate from 1 to 100 percent Relative Humidity.Instead several elements are used,each in a narrow range,with provision for switching elements. Resistance is measured either with a Wheatstone Bridge or by a combination of Current and Voltage Measurements. Most of these must not be exposed to conditions of 100 percent Humidity as the Resulting Condensation may damage the Device.Either they must be operated in a constant Temperature Environment or Temperature corrections must be made. These are Accurate to within plus or minus 2.5 percent or plus or minus 1.5 percent in some cases.Response times are typically of the order of a few seconds.These are currently the most common Electronics Hygrometers. A typical Resistive Hygrometer having a mixture of Lithium Chloride and Carbon which acts as Conducting Film.This is put on an Insulating Substrate between Metal Electrodes. The Resistance of the element changes when it is exposed to variations in Humidity.The higher the Relative Humidity the more Moisture the Lithium Chloride will absorb,and the lower will be it's Resistance. The Resistance of the Sensing unit is a Measure of the Relative Humidity.Resistance should be Measured by applying Alternative Current (A.C) to the Wheatstone Bridge. D.C. Voltage is not applied beacause it tends to Breakdown the Lithium Chloride it it's lithium and Chlorine Atoms.The Current flow is a Measure of the Resistance and hence of the Relative Humidity. There are different types of Hygrometer are as follows. 01)Resistive Hygrometer 02)Capacitive Hygrometer 03)Microwave Hygrometer. 04)Aluminium Oxide Hygrometer. 05)Crystal Hygrometer. For more details,please visit http://elctronicsengineering.blogspot.com/ |
|
 |
|
No reactions yet.
Please login or sign up to rate this intel.
Please login or sign up to add a comment.
The copyright for this content entitled "What is mean by Hygrometer?" has been specified by the contributor as:
All Rights Reserved
This content may not be copied, distributed or adapted by anyone under any circumstances.
|
 |
May, 2012
2008
January, February, March, April, May, June, July, August, September, October, November, December
2009
January, February, March, April, May, June, July, August, September, October, November, December
2010
January, February, March, April, May, June, July, August, September, October, November, December
2011
January, February, March, April, May, June, July, August, September, October, November, December
2012
January, February, March, April, May
|
|
Not a member yet?
Qondio is a powerful network for making it online. If you have a website to
promote, we can help.
Sign up and get in on the action.
|
|
Welcome to Qondio! Discover the awesome power this network can deliver by going to our About page. Or you could skip straight to the Sign Up form.
|
|